Tel
Add
TEMAK standard salt spray test chamber is made of PVC or fiberglass reinforced plastic (FRP). The test chamber is designed to meet industry standards, minimizing the risk of misinterpretation. It includes various fixtures for large samples, with sample placement designed to comply with standards. The test chamber features multiple safety mechanisms, including low water level alarms, over-temperature protection, low saltwater solution alarms, and short-circuit overvoltage protection.
| Specification | KTM-SST900P | KTM-SST1200P/F/T | KTM-SST1600P/F/T | KTM-SST2000P/F/T | |||
Series/Material | P | P | F/T | P | F/T | P | F/T |
| Internal box volume (L) | 270 | 432 | 507 | 800 | 1040 | 1000 | 1300 |
| Internal box dimensions W*D*H (mm) | 900*600*500 | 1200*600*600 | 1200*650*650 | 1600*1000*500 | 1600*1000*650 | 2000*1000*500 | 2000*1000*650 |
| External box dimensions W*D*H (mm) | 1520*905*1370 | 1813*886*1410 | 2710*890*1320 | 2450*1250*1500 | 3070*1245*1438 | 2700*1500*1250 | 3470*1245*1438 |
| Test standard | CNS, JIS, ASTM, GB/T2423.17, GB/T10125 | ||||||
| Test method | NSS (Neutral); ASS (Acidic); CASS (Copper-Accelerated) | ||||||
| Temperature range (°C) | 35°C to 63°C | ||||||
| Fog deposition rate | 1.5 ± 0.5 ml/80 cm²/1 hr (average value over 16 hours) | ||||||
Fog deposition rate difference | ±0.5 ml/80 cm²/h | ||||||
| Salt spray (NSS/ASS) | Test chamber: 35°C ± 1°C; Saturated air tank: 47°C ± 1°C | ||||||
| Copper accelerated test (CASS) | Test chamber: 50°C ± 1°C; saturated air tank: 63°C ± 1°C | ||||||
Sealed top cover | Angle of 100 degrees, ensuring no water droplets fall from the top, using a water-sealed design to prevent salt fog leakage | ||||||
| Saturated air tank | Made of SUS#316 material, cylindrical design for stable airflow, copper spiral air tubes to ensure air is fully saturated | ||||||
| Brine storage tank (L) | 17.5 | 20 | 6.5 | 50 | 6.5 | 50 | 6.5 |
| Noise (dB) | ≤65 (noise will be affected by surrounding echoes, causing noise values to increase; pay attention to the environment in which the equipment is placed) | ||||||
Total weight (kg) | 400 | 640 | 750 | 1540 | 1540 | 2000 | 2000 |
Voltage (V) | AC 220V single-phase three-wire system | ||||||
Sample rack | 1 set (customizable) | ||||||
Spraying method | Bernoulli principle absorbs salt water and then atomizes it, with uniform atomization | ||||||
Spraying mode | Continuous or intermittent spraying, with adjustable cycle period | ||||||
| Nozzle | Made with a special glass nozzle, allowing adjustment of spray volume and spray angle | ||||||
| Air supply system | Air pressure is adjusted in two stages at 1 kg/cm². The first stage is for coarse adjustment, and the second stage is for fine adjustment. It is equipped with an air filter. | ||||||
| Air inlet | Air source requirement: 5 kg/cm²; connection pipe diameter: 8 mm | ||||||
| Exhaust outlet | Exhaust pipe diameter (P: 1-1/4 inches) (F: 2 inches) | ||||||
| Water inlet | Deionized water source (pure water), connection pipe diameter: 1/4 inch | ||||||
| Drain outlet | Drain pipe diameter: 1/2 inch | ||||||