The xenon arc test chamber is a specialized testing device designed to simulate the natural aging process of materials under environmental conditions. It utilizes high-energy radiation from xenon arc lamps to mimic sunlight exposure. By adjusting parameters such as lamp power, irradiation duration, and chamber temperature and humidity, the simulated environment is precisely controlled to accelerate the natural aging process of materials. This enables the rapid acquisition of evaluation data on material aging performance within a short timeframe.
Test Standards:
AATCC TM 16. AATCC TM 169. ASTMC 1442. ASTM D 2565. ASTM D 3424. ASTM D 4303. ASTM D 4355. ASTM D 4434. ASTM D 4459. ASTM D 4798. ASTM D5071, ASTM D6551, ASTM G155, ISO 105 B02, ISO 4892-2, SAE J2412, SAE J2527.
| Specifications | KTM-XTA6500D | KTM-XTA6500 |
| Series | Rotary Xenon Lamp | Flat-Panel Xenon Lamp |
| Inner box volume (L) | 438 | 576 |
Inner box dimensions W×D×H (mm | 760*760*700 | 800*800*900 |
| External box dimensions W×D×H (mm) | 1230*2080*1650 | 1325*1895*2100 |
| Xenon lamp tube | Genuine Imported 6500W Water-Cooled Xenon Arc Lamp 280~1700nm | |
| Spectral distribution | 5W/m² ±35% at 280-320nm | |
| 63W/m² ±25% at 320~400nm | ||
| 580W/m² ±10% at 400–780nm | ||
| 492W/m² ±20% at 780–1700nm | ||
| Irradiance | At 340 nm: 0.32–1.5 W/m² (quartz + borosilicate glass) | |
| At 420 nm: 0.6–2.75 W/m² (quartz + borosilicate glass) | ||
| At 300–400 nm: 32–150 W/m² (quartz + borosilicate glass) | ||
| At 300nm–800nm: 250–765 W/m² (quartz + borosilicate glass) | ||
| At 300nm–3000nm: 650–1000 W/m² (quartz + borosilicate glass) | ||
| Lamp Control | Programmable cycle settings allow adjustment of lamp intensity, duration, and repetitive execution intervals | |
| Exposure Area | ≥5000 cm² | |
| Filter | S-type borosilicate / S-type borosilicate; Service life ≥4000 hours | |
| Rainfall Flow Rate | 2.1±0.1 L/min and 1.05±0.05 L/min (adjustable) | |
| Xenon Lamp Cooling | Circulating water cooling system effectively dissipates xenon lamp heat to ensure stable light emission | |
| Xenon Lamp Igniter | Electronic xenon lamp voltage regulator (includes ignition ICB) | |
| Noise (dB) | ≤65 dB (noise levels may increase due to surrounding echoes; note placement environment) | |
| Total Weight (kg) | 1200 | 1280 |
| Voltage (V) | AC 380V, three-phase five-wire system | |
| Test Hole Dimensions (mm) | φ100mm (not applicable for rotary drum xenon lamps) | |
| Sample Shelf | 2 pieces SUS304 stainless steel sample holders; 2 sets SUS304 stainless steel supports | |
| Humidity Water Requirements | Deionized water; pH 6–7; water conductivity <20 μs/cm | |