Tel
Add
Sand and dust test chambers are used to evaluate the sealing performance of product enclosures, primarily for testing the IP5X and IP6X ratings specified in enclosure protection standards. They assess the adaptability of all mechanical, optical, electrical, electronic, electrochemical, and electromechanical devices exposed to dry blowing sand, blowing dust, or settling dust conditions. These chambers comply with multiple testing specifications including DIN, IEC, GB, ISO, and JIS.
Test Standards:
Chinese Standards: GB/T2423.37-2006, GB/T4208-2017, GB/T 11606-2007
Electrical and Electronic Standards: IEC60068-2-68:1994, IEC60529:2013
Chinese Military Standards: GJB150.12A-2009
| Specifications | KTM-DT1000P | KTM-DT1000FC | KTM-DT2000FC | KTM-DT4E1000P | KTM-DT10E2000P | KTM-DT27E3000P |
| Internal box volume (L) | 1000 | 1000 | 2000 | 3375 | 10000 | 22500 |
Internal box dimensions W*D*H (mm) | 1000*1000*1000 | 1000*1000*1000 | 2000*1000*1000 | 1500*1500*1500 | 2000*2000*2500 | 3000*2500*3000 |
| External box dimensions W*D*H (mm) | 1500*1400*1950 | 1500*1400*1950 | 2520*1390*2150 | 1720*2150*2265 | 2250*2650*3200 | 3600*3250*3000 |
| Dust Dispersion Method | Top-down dust blowing method; variable-frequency dust circulation system with inverter-controlled blower | |||||
| Dust Consumption | 2kg/m³ dust holding capacity | |||||
| Airflow Speed Adjustment | Adjustable air velocity: 1~10 m/s | |||||
| Dust Dehumidification | Built-in heated automatic dust dehumidification line Automatic dehumidification prevents dust clumping and difficult cleanup | |||||
| Dust Collection Design | Synchronous vibration dust equalizer Promotes dust flow into collection box, ensuring consistent dust removal throughout chambe | |||||
| Sample Negative Pressure | Sample enclosure tested with negative pressure extraction Pressure differential: 2KPa | |||||
| Dust Measurement | Quality sampling method and special air flow meter | |||||
| Pressure Relief Device | Pair with bag-type dust filter, one set | |||||
| Temperature and Humidity Measurement | Original dust-resistant electronic temperature and humidity sensor | |||||
Noise Level (dB) | ≤71 (Note: Noise levels may increase due to surrounding echoes; pay attention to equipment placement environment) | |||||
| Total Weight (kg) | 750 | 750 | 1400 | 1200 | 1850 | 2150 |
| Voltage (V) | AC 380V Three-phase five-wire system | |||||
| Window Dimensions (mm) | 600*700 | 350*500 | 240*300 | 600*600 | ||
Test Hole Dimensions (mm) | Ф50 | |||||
| Number of Test Holes | 1 | |||||
| Storage Shelf | 2 pieces | 4 pieces | Customization required | |||
Control Syste | TEMAK proprietary controller (Model: KTM-DUST | |||||
Communication Capabilities | RS232 & 485 LAN | |||||
| Chamber shell color | RAL 1053 | |||||