Tel
Add
A liquid to liquid thermal shock chamber is a specialized device used to simulate the liquid impact environment that products may encounter during use, and to test the sealing performance, waterproof performance, corrosion resistance, and structural strength of products.
| Specification | KTM-LSK-AC | KTM-LSK-AD |
Suspended basket dimensions W*D*H (mm) | 120*120*150 | 215*195*350 |
Preheating oil tank dimensions W*D*H (mm) | 330*400*450 Initial filling capacity approx. 33 liters of liquid oil | 325*430*510 Initial filling capacity approx. 60 liters of liquid oil |
Precooling oil tank dimensions W*D*H (mm) | 220*400*350 Initial filling capacity approx. 33 liters of liquid oil | 280*430*510 Initial filling capacity approx. 54 liters of liquid oil |
External box dimensions W*D*H (mm) | 1600*1355*2110 | 1720*1680*2370 |
Temperature indication error (°C) | ±1.0 | |
Temperature setting accuracy (°C) | 0.1 | |
| Time setting accuracy (s) | 0.1 | |
| Temperature deviation (°C) | ≤ Soil 2.0 (segment-adjustable deviation compensation within the controller) | |
| Temperature uniformity (°C) | ≤1.0 | |
| Temperature fluctuation (°C) | ≤土0.5 | |
| Heat transfer medium | Recommended use of D02 TS or D03 | |
| Pre-cooling oil tank temperature | -10℃~-70℃, RT~-70°℃≤90min | |
| Pre-heating oil tank temperature | +60°C~+180℃, RT~+180°C≤70min | |
| Shock temperature range | -55℃~+125℃; -65 ℃~+150℃ | |
Suspended basket movement time (s) | ≤10 | |
| Recovery time (min) | 1 | |
Noise (dB) | 70 (Noise is affected by surrounding echoes, which can increase noise levels. Please pay attention to the environment in which the equipment is placed.) | |
| Test load | IC 2.0 kg (Maximum load capacity of the basket: 10.0 kg) | IC 3.0 kg (Maximum load capacity of the basket: 15.0 kg) |
Total weight (kg) | 980 | 1100 |
| Voltage (V) | AC 380V three-phase five-wire system | |
| Suspended basket design | Customizable for the semiconductor industry | |
| Sample movement mechanism | Utilizes a servo motor to drive the lead screw, enabling the hoist basket assembly to move horizontally left and right; employs high-precision buffer cylinders to drive the hoist basket frame vertically up and down | |
| Heat transfer method | Features titanium tube immersion-type coil heat transfer | |
| Oil and gas recovery device | An oil-gas recovery device is installed on the side wall above the high-temperature liquid tank to minimize liquid oil consumption | |
| Heating method | Stainless steel electric heating tubes with balanced temperature control via P.I.D. + P.W.M. + S.S.R. | |
| Liquid oil stirring | A long-shaft stirrer is installed at the top of the pre-cooling zone oil tank, driven by a reducer motor to ensure thorough heat exchange between the liquid oil and the evaporator | |
| Cooling method | Water-cooled | |